Chapter 7. Configuring the DCE Port
7-6 IQ Probe User Manual 61200214L1-20
DLCI
Enter the DCE port's DLCI. Range is 16 to 1007.
DBU DLCI
Enter the far end DLCI for each PVC used for dial backup. Only the IQ
Probe that originates the call is required to have this option set. Range is
16 to 1007.
DBU Phone Number
The phone number entry stores the phone number that is used when the
IQ Probe triggers auto dial backup in case of port or PVC failure. The
phone number should correspond to a location that is equipped with an
“Adtran Safety Net” device that is capable of restoring the PVC which is
designated by the DBU DLCI element.
If auto DBU is triggered by port failure, then the DBU C
ALL
O
RDER
ele-
ment determines the order of a dialing list for alternate backup locations.
DBU on Inactive
This option works in conjunction with the dial backup criteria option W
ITH
PVC I
NACTIVE
. For DBU O
N
I
NACTIVE
option to have an effect on auto DBU
operation, the W
ITH
PVC I
NACTIVE
option must be set to E
NABLE
. See Dial
Backup Configuration on page 8-1.
If DBU
ON
I
NACTIVE
is set for E
NABLED
and the PVC designated by the
DLCI element in the table entry goes to an inactive or unknown state, the
IQ Probe will dial the phone number designated by the DBU P
HONE
N
UM
-
BER
element in the table entry.
G
ROUP
is a special case in which all PVCs that are part of a group must be
inactive or unknown before the auto DBU process is triggered. This special
case is treated as a port failure in which DBU C
ALL
O
RDER
entry applies.