Chapter 10. Statistics
61200214L1-20 IQ Probe User Manual 10-31
DBU Port Statistics Available on Front Panel
DBU statistics are only available if a dial backup card is installed.
DBU Status
Current state of the DBU circuit.
Time in DBU
The amount of time (in seconds) that the unit has been in dial backup
mode.
Frames In
Total received frames since the unit went into dial backup mode (or since
last reset).
Frames Out
Total transmitted frames since the unit went into dial backup mode (or
since last reset).
Errored Frames
Total errored frames received since the unit went into dial backup mode
(or since last reset).
CRC Errors
Number of frames received on the dial backup circuit with CRC viola-
tions.
Abort Frames
Total frames received on the dial backup circuit without a closing flag.
Octet Align
Number of frames received on the dial backup circuit with a bit count that
does not fall on 8-bit boundaries.