ADTRAN 1200214L1 Especificaciones Pagina 111

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 176
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 110
Chapter 10. Statistics
61200214L1-20 IQ Probe User Manual 10-7
Octet Align
Number of frames received with a bit count that does not fall on 8-bit
boundaries. This transmission error is also reflected in the D
ISCARD
F
RAME
field.
Length Error
Number of frames received with fewer than 5 octets or greater than 4500
octets. This link violation is also reflected in the D
ISCARD
F
RAME
field.
EA Violation
Number of frames received with an error in the E
XTENDED
A
DDRESS
(EA)
bit field of the frame relay header.
Encapsulation Error
Number of frames received on the management DLCI that have RFC 1490
errors.
Inactive DLCI
Number of frames received on an inactive DLCI.
Invalid DLCI
Number of frames received on a DLCI that is out of range. The valid DLCI
range is 16-1007.
Unrouteable
Number of frames received on the management DLCI with an IP address
that does not match the IQ Probe IP address.
DCE Port Statistics
Information given is for the DCE port since the last reset. See Figure 10-4
on page 10-9 and Figure 10-5 on page 10-10 for both formats of the DCE
P
ORT
S
TATISTIC
screens.
Leads On
If a lead is active on the DCE port, it is listed in the V
IEW
S
TATISTICS
menu.
Signaling State
Indicates if the signaling state is currently up or down.
Vista de pagina 110