Chapter 3. Operation
3-6 IQ Probe User Manual 61200214L1-20
VT-100 Terminal Connection and Operation
To control the IQ Probe using a VT-100 terminal, follow this procedure:
1. Set the IQ Probe baud rate to match the terminal through the front
panel (maximum rate is 38.4k). Select 1 C
ONFIG
, then 4 C
ONTROL
P
ORT
.
2. Using the ADTRAN-provided VT-100 terminal adapter, connect the
COM port of a VT-100 compatible terminal or equivalent to the eight-
pin modular jack labeled Control on the rear of the IQ Probe. This
connection is used for both local and remote configuration.
3. Open the connection and press
Enter
repeatedly until the L
OGIN
M
ENU
appears (Figure 3-3 on page 3-7).
4. Select L
OCAL
L
OGIN
to configure the IQ Probe unit connected to the
terminal.
5. Select R
EMOTE
L
OGIN
to configure a remotely located IQ Probe unit.
6. For remote applications, at the remote DLCI prompt, enter the outgo-
ing DLCI (see the following note) by pressing
1
, then
Enter
, entering
the DLCI number, and pressing
Enter
again.
7. Next, select B
EGIN
R
EMOTE
S
ESSION
by pressing
2
and
Enter
. When
entering the DLCI for a remote application, enter the DLCI associated
with the local unit that you are logged in to (not the far end DLCI).
8. Enter the password. The factory default password is adtran. The
main menu will appear (Figure 3-4 on page 3-7).
9. Make selections by entering the number corresponding to the chosen
parameter. Press
ESC
to return to the previous screen.
If the wrong DLCI is entered or a network problem exists, the
screen freezes at the Press any key to continue
prompt. Press
CNTL + L
twice to return the unit to the Login
screen.
In the upper right-hand corner of the VT-100 screen, LOCAL or
REMOTE is displayed, indicating which unit the current screen
represents. See Figure 3-3 on page 3-7.