Command Reference Guide Line (Console) Interface Config Command Set
61950860L1-35D © 2003 ADTRAN, Inc. 517
databits <option>
Use the databits command to set the number of databits per character for a terminal session. This value
must match the configuration of your VT100 terminal or terminal emulator software. The default is 8
databits per character. Use the no form of this command to return to the default value.
Syntax Description
<option>
Specifies the number of databits per character
7
7 data bits
8
8 data bits
Default Values
<option> 8
Command Modes
(config-con 0)# Console Interface Configuration Mode required
Command History
Release 1.1 Command was introduced
Usage Examples
The following example configures 7 databits per character for the console terminal session:
(config)#
line console 0
(config-con 0)#
databits 7