ADTRAN Stub Routing Especificaciones Pagina 167

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 568
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 166
Command Reference Guide Global Configuration Mode Command Set
61950860L1-35D © 2003 ADTRAN, Inc. 167
interface loopback <label>
Use the interface loopback command to create a virtual interface that can be assigned layer 3 and higher
properties and is always up unless the router is shut down. Use the no form of this command to delete a
configured loopback interface.
Syntax Description
<label>
Specifies the numerical virtual loopback interface identifying label (valid range: 1
to 1024)
Default Values
By default, there are no configured loopback interfaces.
Command Modes
(config)# Global Configuration Mode required
Command History
Release 3.1 Command was introduced
Usage Examples
The following example creates a loopback virtual interface (labeled 1) and enters the Loopback Interface
Configuration Mode:
(config)#
interface loopback 1
(config-loop 1)#