ADTRAN Stub Routing Especificaciones Pagina 377

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 568
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 376
Command Reference Guide SHDSL Interface Configuration Command Set
61950860L1-35D © 2003 ADTRAN, Inc. 377
loopback remote
Use the loopback remote command to send a loopback request to the remote unit. This command is
functional only in CO operating mode (see the section equipment-type [co | cpe ] on page 372). Use the no
form of this command to send a loopdown code to the remote unit to deactivate the loopback.
Syntax Description
No subcommands.
Default Values
No defaults necessary for this command.
Command Modes
(config-shdsl 1/1)# SHDSL Interface Configuration Mode required.
Command History
Release 3.1 Command was introduced
Usage Examples
The following example initiates a remote line loopback:
(config)#
interface shdsl 1/1
(config-shdsl 1/1)#
loopback remote