Application Views Adtran DSU IV Application (AdDSUIVApp)
Device Management Page 91 Adtran DSU/CSU
Test Operation View
Access: From the Icon Subviews menu for the
AdDSUIVApp, select Test Operation.
This view provides the following information.
Test Command
A Set for this option performs one of the DSUIV
test operations. Possible operations are
exitTest, dteLoopLL, loopOnlyRT, dteOnly,
dtePattern, testPattern, selfTest,
remoteLoopPattern, and remoteLoopDteData.
Test Pattern
This option selects a test pattern to be used
during test commands with patterns. Possible
patterns are pattern2047, pattern511,
stress1, stress2, stress3, stress4,
dataFromDte.
DBU Connection Test
This option performs a DBU Connection Test. The
Set value selects the phone number to dial the
remote unit. A value of 0 selects the Dial Backup
string, 1 to 10 selects the stored phone number
from the list in the phone number table.
Remote Unit Address
This option selects the address of the remote unit
for remote test operations.
Insert Error
A Set operation will insert one error into the
transmitted test pattern during pattern tests.
Clear Error
A Set operation will clear the error counters.
Error Count
This value indicates the number of errors
accumulated by the test pattern detector.
Table 9: DBU Status
Value Meaning
S4WDBU-OOS Getting TEI
S4WDBU-NoRx Registering SPID
S4WDBU-NoSx No Rx Signal
TransmitTestPattern Connected & Transmitting
Test Pattern.
InLoopBack Connected & In Loopback
Reserved Reserved
InTestFromTelco In Test from Telco.
DBUCardPresent DBU card is present.