Application Views Adtran IQ Probe Status App (AdIQProbStaApp)
Device Management Page 63 Adtran DSU/CSU
Max Thruput Tx
The maximum throughput the port transmitted
for the interval.
Max Thruput Rx
The maximum throughput the port received for
the interval.
Avg Utilization Tx
The average utilization the port transmitted for
the interval.
Avg Utilization Rx
The average utilization the port received for the
interval.
Max Utilization Tx
The maximum utilization the port transmitted for
the interval.
Max Utilization Rx
The maximum utilization the port received for the
interval.
DBU Active Time
Time in seconds the DBU port was active.
CRC Errors
Number of frames received with CRC errors.
Abort Frames
Number of frames received without proper flag
termination.
Octet Violations
Number of frames received with a bit count not
divisible by eight.
Discarded Frames
Number of frames discarded by the IQ unit.
Length Errors
Number of frames received that is less than 5
bytes or greater than 4500 bytes.
Encapsulation Errors
Number of frames destined for the IQ IP stack
with that does not meet the FRF.3 IA.
Unroutable Frames
Number of frames received on a management
DLCI destined for the IQ unit and have the wrong
IP address.
DBU Daily Status Table View
Access: From the Icon Subviews menu for the
AdIQProbStaApp, select DBU Daily Status Table.
This view displays the following information.
Slot Index
The instance for this entry.
Frames Rx
The number of frames the port received for the
day.