Application Views Adtran DSU IQ Configuration Application (AdDSUIQConApp)
Device Management Page 46 Adtran DSU/CSU
Timeout, T392
Sets the timeout in seconds between polling
intervals from 5 to 30 seconds.
Error Events, N392
Sets the number of error events for the frame
relay management from 1 to 10.
Error Window, N393
Sets the error window (polling events) for the
frame relay management.
Signaling Response
Determines how the IQ device will respond to
polls from the DTE device during network failure.
If set to always on, the IQ will respond to polls
during a network failure.
PVC Configuration Table View
Access: From the Icon Subviews menu for the
DSUIQConfigApp icon, select PVC Configuration.
This view provides PVC Configuration
information. Double-click on an entry to open the
PVC Configuration Detail view.
Config Index
The index identifier for this PVC entry.
DLCI Address
The address for this PVC entry, ranging from 16
to 1007.
CIR
The Committed Information Rate (CIR) for this
PVC in Kbps.
Sequence Num Option
The sequence number allows the IQ to detect lost
frames across the frame relay service. This option
should be disabled for PVCs that do not have IQ
on both ends.
Delay Pkt Option
Delay Packet Option for this PVC allows the IQ to
sample round trip delay across the frame relay
service. This option should be disabled for PVCs
on both ends.
DBU DLCI
This object is used when this PVC entry is used
for dial backup.
Stats Control
Statistics Control option. Possible values are
auto, enable, and disable.