Application Views Adtran TSU IQ+ Status Application (AdTSUIQPStaApp)
Device Management Page 87 Adtran DSU/CSU
DSX Daily Status Table View
Access: From the Icon Subviews menu for the
AdTSUIQPStaApp, select DSX Daily Status Table.
This view displays the following information.
Slot Index
The instance for this entry.
Unavail Secs
Amount of time in seconds the DSX port is
unavailable due to test or in an inactive state.
State Change
Number of changes in the DSX port state. This
includes all normal, inactive, and test state
transitions.
Signal Loss Event
An active state represents one or more signal
loss events.
Loop Back Event
Active state represents one or more loopback
events.
AIS Event
Active state represents one or more AIS events.
AIS is triggered by unframed all ones condition
from the DSX service provider.
Red Alarm Event
Active state represents one or more AIS events.
AIS is triggered by unframed all ones condition
from the T1 service provider.
Yellow Alarm Event
Active state represents one or more yellow alarm
events. Yellow alarm is an indication the service
provider has lost frame alignment.
PLL Alarm Event
Active state represents one or more PLL alarm
events. PLL alarm is an indication that the
transmit and receive side of the DSX interface are
not looped timed. This will occur when both ends
of the DSX are set to provide timing.
Path Code Violations
Count of path code violations received. Path code
violations are a errors in the frame bit positions
for D4 and ESF CRC errors when set for ESF.
Line Code Violations
Count of line code violations received. Line code
violations are a combination of BPVs that are not
part of B8ZS code and excess zeros. Excess zeros
are eight or more consecutive zeros when set for
B8ZS and fifteen or more consecutive zeros when
set for AMI.
Comentarios a estos manuales