Application Views Adtran TSU ESP Application (AdTSUESPApp)
Device Management Page 105 Adtran DSU/CSU
This opens the TSU ESP Current & History Status
View that is described below.
Current Status
The current status of the TSU ESP. See Table 11.
Status History
The TSU ESP status history of alarms, errors, and
tests. It is a bit map represented as a sum,
multiple bits can be active simultaneously. See
Table 11 for values.
Test Operation View
Access: From the Icon Subviews menu for the
AdTSUESPApp icon, select Test Operation.
This view provides the following information.
DTE Loopback
This allows you to turn the TSU ESP DTE
loopback either on or off.
Current/History Status
Table 11: Alarm Indicators
Value Definition
noAlarm No alarm present
RcvYellow Received Yellow Alarm
XmtYellow Transmit Yellow Alarm
RcvBlue Receive Blue Alarm
XmtBlue Transmit Blue Alarm
RcvRed Receive Red Alarm
RcvLos Receive Loss of Signal
LocalLB Local Loopback
RemoteLB Remote Loopback
XmtPattern Transmit Pattern
Generation
CodeViol Code Violation
RcvBPVS Receive Bipolar Violations
FrmBitErrs Frame Bit Errors
PhaseLock Phase Lock Loop Alarm
DialBackup Dial Backup
Table 11: Alarm Indicators (Continued)
Value Definition