Appendix A. System Event Logging
A-4 ATLAS 800
PLUS
User Manual 61200226L1-1
Table A-3. Source: Nx 56/64
Event Category Console Log String Front Panel
Display String
Clock Slip Alarm Active Major Nx 56/64 Clock Slip Alarm
Active
Nx CLK SLIP -A
Clock Slip Alarm Cleared Major Nx 56/64 Clock Slip Alarm
Cleared
Nx CLK SLIP -I
Pll Alarm Active Major Nx 56/64 PLL Alarm Active Nx PLL ALM -A
Pll Alarm Cleared Major Nx 56/64 PLL Alarm Cleared Nx PLL ALM -I
External Clock Alarm Major Nx 56/64 External Clock Alarm
Active
Nx EXT CLK ALM-A
External Clock Alarm
Cleared
Major Nx 56/64 External Clock Alarm
Cleared
Nx EXT CLK ALM-I
Excessive Zeros from
DTE
Warning Nx 56/64 Excessive Zeros Alarm Nx XS0 ALM-A
Excessive Zeros condition
cleared
Warning Nx 56/64 Excessive Zeros Alarm
Cleared
Nx XS0 ALM-I
Bilateral Loopback
Activated
Warning Nx 56/64 Bilateral Loopback
Active
Nx BI-LAT LBK -A
Bilateral Loopback
Deactivated
Warning Nx 56/64 Bilateral Loopback
Cleared
Nx BI-LAT LBK -I
511 Test Pattern Activated Warning Nx 56/64 511 Test Pattern Active Nx TEST PTRN -A
511 Test Pattern
Deactivated
Warning Nx 56/64 511 Test Pattern
Cleared
Nx TEST PTRN -I
DTR Asserted Information Nx 56/64 DTR Asserted n/a
DTR Dropped Information Nx 56/64 DTR Dropped n/a
RTS Asserted Information Nx 56/64 RTS Asserted n/a
RTS Dropped Information Nx 56/64 RTS Dropped n/a
DCD Asserted Information Nx 56/64 DCD Asserted n/a
DCD Dropped Information Nx 56/64 DCD Dropped n/a
CTS Asserted Information Nx 56/64 CTS Asserted n/a
CTS Dropped Information Nx 56/64 CTS Dropped n/a