Chapter 12. SNMP Management
12-4 ATLAS 800
PLUS
User Manual 61200226L1-1
When enabled, ATLAS 800
PLUS
sends alarm traps to the each member of the
trap destination list upon detecting status bit changes in dsx1LineStatus. Each
status change sets an event bit = 1 in the adDS1LineEvent variable in the DS1
alarm table. If you have previously set the corresponding enable bit = 1 in
the adDS1LineArm variable and adDS1AlarmEnable = On, then
ATLAS 800
PLUS
sends an alarm trap message. A single alarm trap message
may report multiple event changes. ATLAS 800
PLUS
clears the event bits af-
ter sending the trap message or sending the response to a Get request for the
adDS1LineEvent variable.
DS1 Alert Traps
RFC1406 also defines a series of Current and Total Alert threshold values.
You can enable ATLAS 800
PLUS
to send an alert trap message to each mem-
ber of the trap destination list when accumulated error statistics exceed
these threshold values. Table 12-4 describes the alert traps supported by
ATLAS 800
PLUS
for events that have occurred in the last 15-minute interval.
Table 12-3. DS1 SNMP Traps
Alarm Severity Description
adATLAS800NoAlarm
Warning No alarms are present.
adATLAS800RxYellow
Minor The Far end is experiencing Red Alarm
(a.k.a. Yellow Alarm).
adATLAS800TxYellow
Warning The Near end is sending Loss Frame Indication
(a.k.a. Yellow Alarm).
adATLAS800RxAIS
Minor The Far end is sending Alarm Indication Signal
(a.k.a. Blue Alarm).
adATLAS800TxAIS
Warning The Near end is sending Alarm Indication Signal
(a.k.a. Blue Alarm).
adATLAS800RedAlarm
Major The Near end is experiencing Loss of Frame
(a.k.a. Red Alarm).
adATLAS800LOS
Major The Near end is experiencing Loss of Signal.
Table 12-4. DS1 Current Alert SNMP Traps
Current Alert Severity Description
adATLAS800CurrentES
Warning The current interval errored second threshold has
been exceeded.
adATLAS800CurrentSES
Warning The current interval severely errored second
threshold has been exceeding.
adATLAS800CurrentSEFS
Warning The current interval severely errored framing second
threshold has been exceeded.