61185001L1-1 MX2810 M13 User Manual A-1
Appendix A
Acceptance Test Procedure
OVERVIEW
This document describes the procedures to be used in performing
acceptance testing of ADTRAN’s Total Access MX2810 M13
Multiplexer. It is assumed that the MX2810 has already been installed,
powered-up, equipped and cabled to the DSX-1 and DSX-3 or connecting
equipment (e.g., DCS) according to the specifications described in the
MX2810 Chassis Practice and local operating company procedures.
This Acceptance Test Procedure (ATP) document assumes testing will be
done via bit error rate tests (BERT) between the DSX-3 or associated
connecting equipment and the DSX-1 or associated connecting equipment
using appropriate DS3/DS1 test equipment. An alternate method of
testing involves the use of an ADTRAN Test Access Module (TAM), also
called a Streaker Card (P/N 1185005L1). The TAM provides the ability to
test DS3 and DS1 cabling integrity following chassis installation and
power-up (no MX2810 Common Control Unit cards are required).
Additional TAM information can be obtained from ADTRAN. That
method of testing is well documented in the TAM I&M Practice and will
not be addressed in this document.
The MX2810 is an M13 multiplexer used to consolidate 28 DS1s onto a
DS3. The unit can be equipped in various ways. The first step will be to
take inventory of the equipment installed. This will determine what tests
can be performed. In general, this document will address the following
areas:
Equipment, System and Alarm Configuration
Bit Error Rate Testing