Chapter 11. Dial Plan
61200305L1-1 ATLAS 550 User Manual 11-9
G
LOBAL
P
ARAM
SetsATLAS 550optionswhichapplyto allswitched operations, bothincom-
ing and outgoing calls.
END OF NUMBER
TIMEOUT
Write security: 3; Read security: 5
Sets the length of time ATLAS 550 waits before assuming the outgoing
dialed number is complete. The default value is six seconds. This timeout
will only be invoked if the dialed number does not match one of the pat-
terns set in the Number Complete Template menu (see the section, Nbr
Complete Templates on page 11-9).
AREA CODE
Write security: 3; Read security: 5
The local area code. Use for sending caller ID to the Network.
NBR COMPLETE
TEMPLATES
Write security: 2; Read security: 5
Sets completed number patterns for outgoing calls so that ATLAS 550
recognizes when the phone number is complete. Fields include the index
number (#) and P
ATTERN
. For example, a local number will be 7 digits long
while a long distance (1+ area code + number) will be 11 digits long. The
ATLAS 550 defaults cover almost any installation, and these templates
shouldnot require any additional user input—except for unusual
circumstances. The template allows the use of the following wild card
inputs to define numbers:
NUMBER TYPE
TEMPLATES
Write security: 2; Read security: 5
Sets call type patterns. ISDN interfaces require that a number type be sent
overthe Dchannel when a callis sentor received.A normal RBS trunk does
not send a type designator, but uses prefixes instead. For example, “1 +”
prefix is a national long distance call type while a “011 +” prefix is an inter-
national long distance call type. These templates form a table to permit
ATLAS 550 to translate the RBS prefix into a call type for ISDN and vice-
versa.
# Denotes an entry number. The maximum number of entries is 50. Press I to
insert a new entry and D to delete any entry.
P
REFIX
Setsthe prefixfor thenumber type.Only digits0 and1 areallowed (MAX 6).
X = Any single digit
N = Any single digit 2 through 9
911 =Thisspecificnumber
[1, 2, 3...] = A single digit in this group
The ATLAS 550 default templates should cover all applications and
should not need to be added to by the user except for very rare
circumstances.