Chapter 10. Dedicated Maps
10-4 ATLAS 550 User Manual 61200305L1-1
TO S
LT
/S Write security: 3; Read security: 5
Specifies the slot to use for the second end of a connection. Select this
option, and a list of all of the slots and the modules installed in the slots dis-
plays. Pick the appropriate slot.
P
RT
/PEP Write security: 3; Read security: 5
Selects the port used for the second connection. When you select this
option, a list of all the slots and available modules displays. Select the
appropriate slot.
F
ROM
C
ONFIG
Write security: 3; Read security: 5
Specifies the configuration for the FROM connection. The selections dis-
played in this field are based on the type of module selected in the
FROM S
LT
option. You must input the following information—based on
the module type.
1
ST
DS0
Write security: 3; Read security: 5
Defines the first DS0 for this endpoint. The ATLAS 550 uses DS0s, starting
with this selection, to send andreceive calls to and from the network. This
option is module-dependent.
DS0 S
ELECTION
Write security: 3; Read security: 5
DefinesDS0sforaT1port.UsethisfieldtodefinewhichDS0swillbeused
for this connection. You can enter the DS0s in several ways. For example, to
enter DS0s one through five, enter
1-5
. For DS0s one and five, enter
1,5
.
DSO R
ATE
Write security: 3; Read security: 5
Defines the data rate per DS0. If FROM S
LT
is an Nx port, the data rate per
DS0 must be set. You can choose from 64 kbps or 56 kbps.
The ATLAS 550 does not supportframe relayat aDS0 rateof 56K.