ADTRAN Tracer TRACER 2 x E1 Guía de usuario Pagina 221

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 319
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 220
Ethernet Tools
Multi Protocol Test Set 209
Cable Test Results - Wire Map
When the link is down:
Short: Short-circuit between Tip and Ring wires of a pair or Tip or
ring wire of a pair is connected with an alien wire grounded.
Open: No cable plugged in, remote end open, or either one or two
wires of a pair are not connected.
Short-between-pairs: Short between one or two wires of a pair
with one or two wires of another pair. Short between more than
two pairs, including one or two wires for each pair.
Noise: Excessive noise on a pair most likely caused by a link
partner running in 10/100Mbps forced mode. In this case, no
distance is reported and there is no comparison with any
threshold.
Unknown: No fault has been identified but the link is down. To
maximize the cable test result, it is preferable to have the far end
equipment powered up.
Note: Refer to Ethernet Cables on page 286 for cable pinout.
Vista de pagina 220
1 2 ... 216 217 218 219 220 221 222 223 224 225 226 ... 318 319

Comentarios a estos manuales

Sin comentarios