ADTRAN Tracer TRACER 2 x E1 Guía de usuario Pagina 184

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 319
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 183
Ethernet Traffic Generation & Monitoring Test
172 AXS-200/805/855
Sequence Results
Statistics for Out-Of-Sequence Frames
Out-Of-Sequence is declared when a frame/packet has its sequence
number smaller than the previously received frame/packet. The
out-of-sequence parameters are applied to the main stream only.
³ Seconds: Displays the total number of seconds in which one or
more Out-Of-Sequence event occurred.
³ Count: Displays the total number of times the Out-Of-Sequence
event occurred.
³ Rate: Displays the rate of frames that are received out of order.
³ Threshold: Set the threshold value for Count or Rate as per the
selected type of verdict. See Out-Of-Sequence Pass/Fail Verdict on
page 143.
= PASS
= FAIL
Vista de pagina 183
1 2 ... 179 180 181 182 183 184 185 186 187 188 189 ... 318 319

Comentarios a estos manuales

Sin comentarios