CHAPTER 2
Channelized E1 Interfaces
Configuring Channelized E1 IQ and IQE Interfaces on page 7
Configuring Channelized E1 Interfaces on page 9
Example: Configuring Channelized E1 IQ or IQE Interfaces on page 11
Example: Configuring Channelized E1 Interfaces on page 12
Configuring Channelized E1 IQ and IQE Interfaces
Configuring E1 IQ and IQE Interfaces on page 7
Configuring Fractional E1 IQ and IQE Interfaces on page 7
Configuring NxDS0 IQ and IQE Interfaces on page 8
NOTE: Class-of-service (CoS) rules cannot be applied to an individual channel
configured on channelized IQ and IQE interfaces. You can only apply CoS
rules to the aggregate bit streams.
Configuring E1 IQ and IQE Interfaces
To configure an E1 interface, include the no-partition and interface-type statements at
the [edit interfaces ce1-fpc/pic/port] hierarchy level:
[edit interfaces ce1-fpc/pic/port]
no-partition interface-type e1;
This configuration creates interface e1-fpc/pic/port.
Configuring Fractional E1 IQ and IQE Interfaces
By default, all the time slots on a channelized E1 interface are used. To configure a
fractional E1 interface on a Channelized E1 IQ PIC, perform the following tasks:
1. Include the no-partition statement at the [edit interfaces ce1-fpc/pic/port] hierarchy
level:
[edit interfaces ce1-fpc/pic/port]
no-partition interface-type e1;
This configuration creates interface e1-fpc/pic/port.
7Copyright © 2014, Juniper Networks, Inc.