61184002L3-5B 3
WARNING
The 10/100baseT interface and DS3 interfaces
MUST NOT be metallically connected to
interfaces which connect to the Outside Plant or
its wiring. These interfaces are designed for use
as intra-building interfaces only. The addition
of Primary Protectors is not sufficient protection
in order to connect these interfaces metallically
to OSP wiring.
NOTE
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference
that may cause undesired operation.
Changes or modifications not approved by
ADTRAN could void the user’s authority to
operate this equipment.
NOTE
The Installation instructions found in the text
below are written under the assumption that
either the Total Access OPTI-3 rackmount or
wallmount chassis (P/N 1184003L1 and
1184001L1 respectively) have been properly
installed (including power, alarm, and data
connections).
The OCM plugs directly into the Total Access OPTI-3
RMC or WMC. Both chassis provide two OCM slots.
Fiber Connection and Physical Installation
The Total Access OPTI-3 RMC provides two OCM
slots that are side by side. See Figure 4. The left slot
is slot A and the right slot is slot B. The Total Access
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC)
Installation Code (IC) A
Table 1. Compliance Codes
Three audible alarm outputs including Critical,
Major, and Minor (RMC only)
Three visual alarm outputs including Critical,
Major, and Minor (RMC only)
–20 VDC to –60 VDC input voltage range
+20 VDC to +60 VDC input voltage range
Power consumption between 7 and 10 watts
(typical) per OCM
Operating temperature range of 40°C to +65°C
(installed in RMC)
Operating temperature range of 40°C to +50°C
(installed in WMC)
Storage temperature range 40°C to +85°C
Relative humidity up to 95 percent,
noncondensing
NEBS Level 3, GR-1089-CORE, GR-63-CORE
and UL 60950 compliant
Meets applicable optical and SONET standards
(GR-253, T1.101, T1.105.xx)
2. INSTALLATION
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
After unpacking the unit, inspect it for damage. If
damage is noted, file a claim with the carrier, then
contact ADTRAN
®
Customer Service. Refer to the
Warranty and Customer Service section of this
practice.
Compliance
Table 1 provides the compliance codes for the Total
Access OPTI-3 Controller Module. The OCM
complies with the requirements covered under UL
60950, and is intended for installation in restricted
access locations only in Type “B” or “E” Enclosures.
1184003L1
RMC
OPTI-3
ENABLE
TESTAPS ACO
1184002L3
CRAFT
STATUS
OPTICS
DS3-1
DS3-2
DS3-3
ACO
OPTI-3
ENABLE
TESTAPS ACO
1184002L3
CRAFT
STATUS
OPTICS
DS3-1
DS3-2
DS3-3
ACO
Figure 4. OPTI-3 RMC
Slot A
(working card)
Slot B
(protect card)
Vista de pagina 2