20 61184002L3-5B
5. Test Menu
The OPTI-3 Controller Module provides access to
multiple loopback tests at the OC-3 and DS3
levels. The following tests are provided:
1. OC-3 Line Loop – Provides a loopback in
the OC-3 interface for data being sent into
the OC-3 interface. During this test, an
Alarm Indication Signal (AIS) is sent all
three DS3 interfaces. See Figure 9.
4. DS3 Local Loop – Provides a loopback
for each individual DS3 coming from the
OC-3 network. Any combination of DS3s
may be tested without affecting any other
DS3. See Figure 12.
*Use here of company’s name does not mean company has authorized, tested or approved this product, and should not in any way be construed as an endorsement by company of
ADTRAN’s product.
DS3
AIS
OC3
Figure 9. OC-3 Line Loopback
Figure 12. DS3 Local Loopback
DS3 OC3
Figure 11. DS3 Line Loopback
DS3 OC3
Figure 10. OC-3 Local Loopback
2. OC-3 Local Loop – Provides a loopback
in the OC-3 interface for data being sent
into the electrical DS3 interfaces. All
DS3s are looped during this test. For this
reason, APS MUST BE DISABLED
before this test may be performed. See
Figure 10.
3. DS3 Line Loop – Provides a loopback for
the data being sent from the DS3 side of
the OPTI-3. Any combination of DS3s
may be tested without effecting any other
DS3. See Figure 11.
5. Remove All Loops – Drops all active
loopbacks within the OPTI-3 Controller
Module.
6. Performance Monitoring Menu
The main Performance Monitoring Menu provides
access to PM submenus and allows the user to
reset all performance data registers and clear
errors in the performance summary. The display
reports if the performance monitoring registers
record any errors since the error summary was last
initialized or the Reset Performance Registers
command was last asserted. The following
choices are available from the main Performance
Monitoring Menu:
1. Clear Error Summary
This command initializes all the performance
summary registers and displays.
2. Reset Performance Registers
This command initializes all the performance
registers for the OCM.
3. OC-3 Section and Line
The OC-3 Section and Line portion of the
Performance Monitoring Menu provides PM
data for the Near and Far Ends. This menu
also allows thresholds to specified and enabled
or disabled. The following submenus are
available:
1. Daily – Provides the user with daily
counts of multiple performance
monitoring statistics including Section
Code Violations, Section Errored Seconds
Section Severely Errored Seconds, Line
Code Violations, Line Errored Seconds,
Line Severely Errored Seconds, and Line
Unavailable Seconds.
Comentarios a estos manuales