ADTRAN MX2800 M13 Manual de usuario Pagina 54

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 198
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 53
MX2800 M13 Multiplexer User Manual
3-12 61200290L1-1H
NIU is used to cause the channel to loop up or loop down when it receives an NIU loop-up
or loop-down pattern for more than 5 seconds.
Select Set Multiple
to set a contiguous group or all of the T1/E1s to the same value at the
same time. Refer to “Set Multiple” on page 3-9 for a description of the
Set Multiple option.
T1/E1 Circuit Protection
T1/E1 Circuit Protection determines which circuit is allowed to initiate a protection switch if a
failure in the circuitry for that channel is detected. See Figure 3-10. If a T1/E1 is set to
Disabled, the failure of the circuitry of that one channel does not cause a protection switch. If
set to
Enabled, the failure of a channel causes a protection switch to occur if the Protection
Threshold setting in this menu is exceeded.
Figure 3-10. Circuit Protection Menu
The Protection Threshold setting determines how many of the
Enabled lines must fail before a
card switch occurs. If the failure of a single protected (enabled) line is to cause a card switch,
set the
Protection Threshold to 1. Choices include 1 through 28.
Select Set Multiple to set a contiguous group or all of the T1/E1s to the same value at the
same time. Refer to “Set Multiple” on page 3-9 for a description of the
Set Multiple selection.
Vista de pagina 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 197 198

Comentarios a estos manuales

Sin comentarios