MX2800 M13 Multiplexer User Manual
9-20 61200290L1-1H
DS3MAXNUMSW INT 0, 1, 2, ..., N Maximum number of times per hour
the unit is allowed to switch between
controller cards. If number is exceeded,
the unit will issue a trap
DS3MINSWPERIOD INT 0, 1, 2, ..., N Number of seconds that must pass
after a protection switch before another
protection switch will be allowed
DS3PROT Y/N Y or [N] Identifies status of DS3 protection
switching
• Yes (Y) - enables DS3 protection
switching
• No (N) - disables DS3 protection
switching
DS3RAIRLY Y/N Y or [N] Identifies status of DS3 RAI alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
DS3TLOSRLY Y/N Y or [N] Identifies status of DS3 TLOS alarm
relay
Yes (Y) - enables alarm
No (N) - disables alarm
DS3XCVRLY Y/N Y or [N] Identifies status of DS3 XCV alarm
relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
FMT ENUM One of the following:
•CBIT
•M13
Sets framing format to match the
format of the receive signal at the
network interface
• The framing format s set to CBIT
• The framing format is set to M13
LINELEN ENUM One of the following:
•LONG
•SHORT
Identifies Network DS3 line length
• LONG - exceeds 50 feet.
• SHORT - less than 50 feet.
RMTLPBK ENUM One of the following:
•DISABLE
•EITHER
•FEAC
•CBIT
Indicates whether the unit will respond
to remote loopbacks over FEAC, CBIT,
EITHER, or if remote loopbacks are
disabled
•DISABLE - do not respond
• EITHER - respond over either FEAC
or CBIT
•FEAC - respond over FEAC
• CBIT - respond over CBIT
Table 9-6. TL1 Editing Data Dictionary for DS3 (Continued)
Keyword Type Domain Description