61292023L5-5A Issue 1, May 2004 7
Table 8 describes cable loss for the Total Reach DDS
Nyquist frequency of 13.3 kHz.
Total Reach DDS Trouble Code
The Total Reach DDS system provides a quick
diagnosis in the case of a circuit condition where conti-
nuity is broken. The trouble code type received by a
tester determines whether the open condition is
occurring on the 2-wire local loop or at the customer
premises. In the event of a 2-wire DSL loss of signal,
loss of sync, or open condition caused by an open
conductor or disconnected 2-wire loop, the Total Reach
DDS CO unit will transmit towards the network one of
two trouble codes. The trouble code is dependent on the
installed Total Reach DDS CO unit, but will be either a
Mux-Out-of-Sync (MOS 9Ah), or alternating MOS and
Abnormal Station Code (ASC 9Eh). During similar
Out-of-Service condition of the 4-wire interface on the
customer premise, the Total Reach OCU-R, transmits
an ASC towards the network. Figure 6 depicts the two
Out-of-Service conditions.
During a similar Out-of-Service condition at the
customer premises, the Total Reach OCU-R transmits
upstream into the network as shown in Figure 7.
Figure 7. DDS Trouble Codes
Dual Function LBK Button (SW2)
The Total Reach OCU-R contains a recessed, front
panel mounted momentary-action pushbutton (LBK)
that allows for initiating loopbacks from the OCU-R, as
well as toggling between hardware and software options
settings. The local test capabilities allow for both local
loopback of the OCU-R, as well as looping back the
Total Reach DDS CO unit without test equipment,
dumb terminal, or centralized test coordination.
Pressing the button for 5 seconds or longer will change
the option settings between the hardware (DIP switch)
and the software provisioned settings.
ASC 9Eh
MOS 9Ah
Channel Bank
TR
CO
Unit
TR
OCU-R
DSU/CSU
Open 4-Wire
Customer Interface
Customer Premises
or
Outside Plant
Channel Bank
Open
2-Wire Loop
TR
CO
Unit
TR
OCU-R
DSU/CSU
4-Wire Customer
Interface
Customer Premises
or
Outside Plant
Table 8. Cable Type and Temperature Loss Data @ 13.3 kHz
Plastic Cable dB Loss/kft Paper Cable dB Loss/kft
19 Gauge PIC (0° F)
19 Gauge PIC (70° F)
19 Gauge PIC (120° F)
0.5302
0.6083
0.6610
19 Gauge PULP (0° F)
19 Gauge PULP (70° F)
19 Gauge PULP (120° F)
0.5616
0.6415
0.6955
22 Gauge PIC (0° F)
22 Gauge PIC (70° F)
22 Gauge PIC (120° F)
0.912
1.0258
1.1015
22 Gauge PULP (0° F)
22 Gauge PULP (70° F)
22 Gauge PULP (120° F)
0.9454
1.0606
1.1370
24 Gauge PIC (0° F)
24 Gauge PIC (70° F)
24 Gauge PIC (120° F)
1.2571
1.3982
1.4917
24 Gauge PULP (0° F)
24 Gauge PULP (70° F)
24 Gauge PULP (120° F)
1.2900
1.4324
1.5268
26 Gauge PIC (0° F)
26 Gauge PIC (70° F)
26 Gauge PIC (120° F)
1.6751
1.8469
1.9608
26 Gauge PULP (0° F)
26 Gauge PULP (70° F)
26 Gauge PULP (120° F)
1.6823
1.8568
1.9718