ADTRAN T200 IDSL Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
20 Issue 1, May 2004 61292023L5-5A
NOTE
Real-time terminal update is recommended for
normal terminal operation unless screens are to
be captured or logged to a print file.
5. REMOTE PROVISIONING AND
DIAGNOSTICS
Control Protocol
Remote access to provisioning and status information is
accomplished using ADTRAN Digital System 6
Message protocol, defined in Control and Diagnostic
Procedures Practice, Section 6032991-6. Digital
System 6 is supported by the TPI 108/109 and 105
portable test set and is supported by Hekimian React
2001 Release 1.900 remote test system. The Total
Reach DDS network elements comply with ANSI
T1.107-1995, “Digital Hierarchy Format Specifications
Annex G” which allows remote provisioning, querying,
and performance monitoring via inband control of
network elements.
NOTE
The REACT 2001 GUI software Release 1.900
supports ANSI T1.107-1995.
Remote access is accomplished using a defined set of
inband DS0 byte sequences similar to the latching
loopback sequence. Commands issued through the test
system are recognized by the individual channel unit,
which responds with the appropriate byte sequences.
These inband commands may be used to verify options
via dialogs with REACT 2001 and TPI 108/109 test
sets. Unit CLEI, serial number, provisioning, and
performance information can be retrieved remotely
using the Digital System 6 protocol.
6. DEPLOYMENT GUIDELINES
The Total Reach DDS CO unit and Total Reach OCU-
R use technology intended to eliminate the need for
repeaters and concerns over impairments caused by
typical noise and bridged tap. Listed below are the loop
design guidelines for Total Reach DDS (see Table 7 and
Tab le 9 for more information):
All loops must be nonloaded.
Actual Measured Loss (AML) should not exceed 50
dB at 13.3 kHz (135 ohms termination), the Nyquist
frequency of Total Reach DDS.
NOTE
The 50 dB AML limit includes 6 dB of signal
margin to account for potential near-end cross
talk (NEXT) from other digital services that
may be provisioned in the same binder group.
Loop length should not exceed 50 kft.
Bridged tap tolerant to 12 kft (tests show no degra-
dation to 18 kft).
Background noise level should not exceed 34 dBrn.
Impulse noise should not exceed –40 dBm
(+50 dBrn).
NOTE
Measure noise with 50 kbit weighting charac-
teristic approximating a filter with a passband
of 40 Hz to 30 kHz. Background noise level or
impulse noise level is referenced from 56/64
kbps data rate in TR62310.
Table 9. Total Reach DDS Insertion Loss
Measurements
Total Reach DDS
13.3 kHz compared to 28 kHz for traditional DDS
service
Line Configuration @ 13.3 kHz @ 28 kHz
27 kft 26 AWG 50.12 dB 65.35 dB
36.25 kft 24 AWG 50.00 dB 62.50 dB
50 kft 22 AWG 50.24 dB 59.33 dB
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22