61292023L5-5A Issue 1, May 2004 3
2. INSTALLATION
After unpacking the System Name Total Reach OCU-R,
inspect it for damage. If damage has occurred, file a
claim with the carrier, then contact ADTRAN Customer
Service. Refer to the Warranty and Customer Service
section for further information. If possible, keep the
original shipping container for returning the Total
Reach OCU-R for repair or for verification of shipping
damage.
Shipping Contents
The contents include the following items:
• Total Reach OCU-R For Outside Plant All Rate
DDS Termination Unit
• Total Reach OCU-Remote For Outside Plant Job
Aid
CAUTION
Electronic modules can be damaged by ESD.
When handling modules, wear an antistatic
discharge wrist strap to prevent damage to
electronic components. Place modules in
antistatic packing material when transporting
or storing. When working on modules, always
place them on an approved antistatic mat that is
electrically grounded.
WARNING
• Never install telephone wiring during a
lightning storm.
• Never install telephone jacks in wet locations
unless the jack is specifically designed for
wet locations.
• Never touch uninsulated telephone wires or
terminals unless the telephone line has been
disconnected at the network interface.
• Total Reach DDS-CO unit normally provides
–130 V of span-powering voltage to the Total
Reach OCU-R.
CAUTION
Ensure ground continuity exists between the
unit, the housing, and a known approved
ground source.
Options
The Data Rate is automatically configured from the
Total Reach DDS CO unit. The Total Reach OCU-R has
a single position, board mounted DIP switch (Figure 3).
Figure 3. ADTRAN Total Reach OCU-R
When 0 dB is selected on SW1 (Figure 4), the unit will
transmit a 0 dB AMI signal across the 4-wire customer
interface toward the DSU/CSU. When –10 dB is
selected, the unit will transmit a –10 dB AMI signal
toward the DSU/CSU.
Figure 4. Option Switch
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
1292023
SYNC
CRC
NO
DSU
AP
NTWK
LBK
SC
64
56
19.2
9.6
4.8
2.4
LBK
OCU-R
CUST
LBK
2 WIRE
O
N
1
0 dB -10 dB
SW1