Table 6: show interfaces Gigabit Ethernet Output Fields (continued)
Level of OutputField DescriptionField Name
detail extensive noneEthernet-specific defects that can prevent the interface from passing packets.
When a defect persists for a certain amount of time, it is promoted to an alarm.
Based on the routing device configuration, an alarm can ring the red or yellow
alarm bell on the routing device, or turn on the red or yellow alarm LED on the
craft interface. These fields can contain the value None or Link.
NoneThere are no active defects or alarms.
Link—Interface has lost its link state, which usually means that the cable is
unplugged, the far-end system has been turned off, or the PIC is
malfunctioning.
Active alarms and
Active defects
detail extensiveActive OTN alarms identified on the interface.OTN alarms
detail extensiveOTN defects received on the interface.OTN defects
detail extensiveThe FECmode configured on the interface.
efec—Enhanced forward error correction (EFEC) is configured to defect and
correct bit errors.
gfec—G.709 Forward error correction (GFEC) mode is configured to detect
and correct bit errors.
none—FEC mode is not configured.
OTN FEC Mode
detail extensiveOTN mode.
fixed-stuff-bytes—Fixed stuff bytes 11.0957 Gbps.
no-fixed-stuff-bytes—No fixed stuff bytes 11.0491 Gbps.
pass-through—Enable OTN passthrough mode.
no-pass-through—Do not enable OTN passthrough mode.
OTN Rate
detail extensiveStatus of the line loopback, if configured for the DWDM OTN PIC. Its value can
be: enabled or disabled.
OTN Line Loopback
detail extensiveThe forward error correction (FEC) counters for the DWDM OTN PIC.
Corrected ErrorsThe count of corrected errors in the last second.
Corrected Error RatioThe corrected error ratio in the last 25 seconds. For
example, 1e-7 is 1 error per 10 million bits.
OTN FEC statistics
detail extensiveOTN FEC excessive or degraded error alarms triggered on the interface.
FEC Degrade—OTU FEC Degrade defect.
FEC Excessive—OTU FEC Excessive Error defect.
OTN FEC alarms
detail extensiveOTN OC defects triggered on the interface.
LOS—OC Loss of Signal defect.
LOF—OC Loss of Frame defect.
LOM—OC Loss of Multiframe defect.
Wavelength Lock—OC Wavelength Lock defect.
OTN OC