ADTRAN MX3216 Especificaciones Pagina 34

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 190
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 33
MX3216 System Manual
3-6 61189008L1-1B
Drop and Insert Application
In the drop and insert application (see Figure 3-6), DS1s from one DS3 can be dropped out the
DSX-1 ports. Then, DS1s from the other DSX-1 ports can be inserted into the corresponding
DS1s in the other DS3. Any DS1s not dropped continue on from one DS3 to the other. This
application allows a DS3 to be used to transport DS1s between several sites.
Figure 3-6. Drop and Insert Application Diagram
Table 3-2 shows the equipment needed for a drop and insert application.
Table 3-2. Drop and Insert Application - Required Equipment
Part # Equipment Quantity
1189001L1 MX3 Chassis 1
1189007L1 MX3 Fan Module 1
1189008L1 MX3216 Controller Card 1 (2 for redundancy)
DS3
MX3216
AIS
MX3216
DS3
Drop DS1s
to Local
Equipment
Original DS1s
and inserted
DS1s continue
downstream;
AIS in
unmapped DS1s
Drop DS1s
to Local
Equipment
28 DS1s
from
Central Site
Central Site Remote Site #1 Remote Site #2
DS3
µ Wave/
Leased
DS3
DS3DS3
DS3
µ Wave/
Leased
DS3
AIS
Insert DS1s
to Remote
Location
Original DS1s
and inserted
DS1s continue
downstream;
AIS in
unmapped DS1s
Insert DS1s
to Remote
Location
Vista de pagina 33