Chapter 10. Statistics
10-8 TSU IQ+ User Manual 61200275L1-1
Length Error
Number of frames received with fewer than 5 octets or greater than
4500 octets. This link violation is also reflected in the D
ISCARD
F
RAME
field.
EA Violation
Number of frames received with an error in the extended address
(EA) bit field of the frame relay header.
Encapsulation Error
Number of frames received on the management DLCI that have
RFC 1490errors.
Inactive DLCI
Number of frames received on an inactive DLCI.
Invalid DLCI
Number of frames received on a DLCI that is out of range. The
valid DLCI range is 16-1007.
Unrouteable
Number of frames received on the management DLCI with an IP
address that does not match the TSU IQ+ IP address.
If both management DLCIs are shared,the Encapsulation Error field is
non-applicable. See the section Management DLCI 1 and 2 (DLCI 1 and
2) on page 7-5 for more information.