TRACER 2 x E1 User’s Manual
61280004L2-1C
Section 4 Troubleshooting
43
SES Values in E1A or E1B Performance History Menu
This value indicates the number of Severely Errored Seconds in the E1 data stream.
Possible Cause
When CRC is enabled, a severely errored second is listed when more than 805 CRCs occur
within that second.
When CRC is disabled, an errored second is listed when more than 850 CVs occur within
that second.
Recommended Actions:
1. Check the E1 signal with a BERT test set to determine origin of error.