61280004L2-1C
Section 4 Troubleshooting
39
Recommended Actions:
1. Check the far-end equipment for alarms or a LOS condition.
2. Check the E1 connections at the far-end equipment.
3. Reset the far-end equipment.
UA1 Alarm
This alarm is indicated on the E1A or E1B Status/Configuration/Loopback page.
Recommended Action
Possible Cause (see list below)
The E1 equipment is sending unframed all 1s ........................................... 1,2
Recommended Actions:
1. Reset the upstream equipment and verify normal operation.
2. Verify the presence of an E1 signal at the E1 monitor jack using an E1 test set.
I M P O R T A N T
If problems persist after you have followed the Recommended Actions, contact ADTRAN
Technical Support at (011) 256-963-8716.