6 Section 61150043L1-5, Issue 3 61150043L1-5C
C. Release Pressure in Housing
WARNING
This housing is shipped pressurized to prevent
moisture accumulation during shipment and
storage.
(1) Remove the security box cover located on
the bottom of the housing base using a nut
driver to loosen the 7/16-inch bolt.
(2)
For List 1 (air-core) only: Verify that the
needle valve is closed by hand-tightening
clockwise. DO NOT OVERTIGHTEN.
See Figure 3.
(3) Remove fill valve cap.
(4)
On both models: Fully depress the needle in
the fill valve for at least 30 seconds to
ensure pressure release.
D. Remove the Clamp and Housing Cover
(1) Wipe any debris from the dome and clamp
before removing locking clamp.
(2) Remove the tamper-resistant security bolt
using a 7/16-inch nut driver.
(3) Turn the T-bar counter-clockwise, releasing
the end of T-bolt from the catch.
(4) Remove the clamp.
(5) Hang the clamp over mounting bracket
behind base. See Figure 7.
(6) Remove the dome from the housing base.
(7) Hang the dome on the bracket using the
dome hook.
Figure 6. Circuit Pack Connections
ISDN BRIDLE-R HDSL FNID HDSL HRE HDSL HTU-R ISDN TR-R
CUSTOMER
5
15
7
13
11
41
47
49
55
NETWORK
LOOP 1
GND
NETWORK
LOOP 2
NC
TO CUSTOMER
5
15
7
13
11
41
47
49
55
NETWORK
GND
NC
FROM
CUSTOMER
CUSTOMER
LOOP 1
5
15
7
13
11
41
47
49
55
NETWORK
LOOP 1
GND
NETWORK
LOOP 2
CUSTOMER
LOOP 2
TO CUSTOMER
5
15
7
13
11
41
47
49
55
NETWORK
LOOP 1
GND
NETWORK
LOOP 2
FROM
CUSTOMER
NC
5
15
7
13
11
41
47
49
55
NC
GND
NETWORK
CUSTOMER
NT1
E. Install Circuit Packs
(1) The label on the support case cover provides
a quick reference to color coding, slot
number locations, and the direction the
T400 card MUST be installed. See Figure
8. (Circuit pack #1 and circuit pack #2
MUST be installed in the opposite direction
from circuit pack #3 and circuit pack #4,
resulting in a back-to-back placement of
circuit pack #2 and circuit pack #3.)
A Slot Location Label is placed around the
housing card-edge connectors showing the
proper orientation of the circuit packs.
Labels affixed inside the repeater housings
provide wiring connection information for
each type of repeater.
The Test Access Card, shipped with each
Housing, may be used to assist with
installing and troubleshooting T400 and
T200 circuits and removed for future use.
Refer to the Test Access Card I/M Practice
(61244065L1-5) for more details.
Refer to Table A for Repeater Housing
Capacity Specifications. Heat dissipation
from the circuit packs AND the collection
of heat from solar loading must be
considered to avoid overheating conditions
inside the Environmental Housings.
(2) Open the support case cover by pulling the
spring-loaded plunger.
(3) Remove the shipping supports from the card
guides.