Product Overview MX410/MX412 System Manual
1-2 PRELIMINARY 61189500L1-1B
The major features of the MX410/MX412 are as follows:
19-inch wall mounting or rack mounting, one rack unit high
Front panel data connections
•One V.35 port
Four RJ-45 long-haul DS1 connections (12 on the MX412) with outside plant protection
A four-port Ethernet switch
Non-Blocking DS0 cross connect between all DS1 interfaces and the V.35 port
RJ-45 10Base-T Ethernet connection
Terminal server functionality
FXS port (MX412 only)
DB-9 craft interface for access to Provisioning, Status, Test, and Alarm menus
Management via Telnet over Ethernet connection or VT100 through a local RS-232, DB-9,
craft port
End-to-end Ethernet extension over multiple T1s
Robbed Bit Signaling (RBS) supported on a per DS0 basis
Hot-swappable PSUs with 1:1 redundancy (MX410 only)
Independent power feeds with separate returns
Accepts redundant ±60 to ±22 VDC inputs
Wire-wrap pins for alarms
Manual and remote initiated loopback modes
Meets NEBS Level 3
Comprehensive test features