T1 Surge Protection
Thermistors, and Sidactors limit transients appearing between the Tip and Ring of each pair. Transients
appearing at the power terminals or between input and output pairs are limited by PTC thermistors and a
metal oxide varistor.
T1 Alarm Contact
The Single Channel T1 System alarm contact allows you to monitor the health of your T1 Fiber Link
system. If any of the below faults are present the alarm contact will revert to its normal state:
BPV - Bi-polar Violations
AIS - All One’s Condition
FRM Alarm - Fiber Frame Loss
PWR - DC Power Loss
When all of the above conditions are OK the contact will change from its resting state to indicate that the
system is running and healthy.
Switch Settings
The DIP switch is located on the top surface of the card. You may need to pull the card slightly out of the
card housing to gain sufficient access to the switch.
B8ZS or AMI Encoding
The AMI/B8ZS DIP switch is used to establish the selection of B8ZS (bit 8 zero substitution) or AMI
(alternate mark inversion) line encoding for the T1 input.
Remote Loopback
The remote (RLOOP) loopback DIP switch is provided to allow for remote loop back of the copper T1 line
for trouble shooting purposes.
The loop back function begins at the T1 receive twisted pair, through the T1 LIU (Line Interface Unit), and
then back out the T1 transmit twisted pair. Normal operating position is OFF for All switch positions.
Signal Loop
OUT
IN
RX
TX
RX
TX
TX
RX
CO Side Module
(Remote Side)
SUB Side Module
(Local Side)
T-1 TEST
EQUIPMENT
Fiber
1 2 3 4 5 6
ONON
1 2 3 4 5 6
Turn on RLOOP switch to check
copper wire connection
LLOOP
RLOOP
ON
LBO-15
LBO-7.5
NOT USED
ON - AMI
OFF - B8ZS
1 2 3 4 5 6
RLOOP (Remote Loopback) Switch Diagram
! RLH Industries, Inc.Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com! Page 9