Appendix B. Log Messages
B-12 Express 4110/4120 User Manual 61200176L3-1
Connected <number>
level 5
A call from or to <number> was connected. If no caller ID is available for
the ISDN line then <number> will be blank for incoming calls.
Demand calling ‘<user>’
level 4
A new call is being placed due to incoming packet routed to “idle” inter-
face or bridge packet passing through demand filter. The Connection List
profile used is the one with <user> in the description field.
DEST NOT ISDN
level 4
The number dialed is not ISDN. This is a warning and is most often seen
for POTS calls.
Dial <number>
level 5
The Express 4110/4120 is dialing <number>.
Dialing ...
level 5
A phone on the Express 4110/4120 POTS port is dialing.
Disconnect <number>
level 5
A call from or to <number> was disconnected. If no caller ID is available
for the ISDN line, then <number> will be blank for incoming calls.
Dump <number>
level 5
A call or call attempt to or from <number> has been refused. If no caller
ID is available for the ISDN line, then <number> will be blank for incom-
ing calls.