Chapter 3. Operation
3-10
Quad E1/PRA Module User Manual 61200264L1
» Pattern
Write security: 4; Read security: 5
Test pattern to be transmitted out the port. The following options are available:
» QRSS Results
Write security: 4; Read security: 5
(Test Pattern Results) Indicates sync and errors of received data pattern.
» Clr
Write security: 4; Read security: 5
(Test Pattern Results Clear) Results clear - clears error counters on test pattern
results menu.
» Inj
Write security: 4; Read security: 5
(Test Pattern Error Inject) Injects errors into transmitted test pattern.
ADDITIONAL ATLAS FEATURES
In addition to the Quad E1/PRA Module menu items, additional ATLAS menu
items may be operated in conjunction with the Quad E1/PRA Module. These
are
Factory Restore
,
Run Self Test
,
and
Dedicated Maps
.
> FACTORY
RESTORE
Factory Restore
, a submenu of the ATLAS front panel main menu item
Utilities
(
UTIL
), restores the factory installed default setting for all Quad E1/PRA Mod-
ule parameters. When
Factory Restore
displays, place the cursor on it and
press
Enter
. The unit is restored to preset factory defaults and returns to the
main ATLAS menu.
> RUN SELF TEST
Run Self Test
, a submenu of the ATLAS main menu item
Test
, executes both the
Quad E1/PRA Module internal test and the ATLAS internal test. For additional
information on
Run Self Tes
t see the ATLAS 800 User Manual. When
Run Self
Test
is displayed, place the cursor on it and press
Enter
to execute the test. The
results of the self-test are displayed in the LCD.
> DEDICATED
MAPS
TS0s are used as defined in the
Dedicated Map
. See the ATLAS 800 User Manual
for detailed information.
All ones
framed ones
All zeros
framed zeros
QRSS
pseudorandom pattern with suppression of excess zeros
Defining a port as a E1 or PRA is determined by the way it is assigned in
the Dedicated Map or in the Dial Plan.