ADTRAN 4202023L2 Manual de usuario Pagina 48

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 47
Configure Network Interface Using a VT100 Terminal Smart 16e Shelf User Manual
48 © 2004 ADTRAN, Inc. 64202023L5-1B
Configure Network Interface Using a VT100 Terminal
To set up the Smart 16e Shelf to accept SLIP, async PPP, or Ethernet communication from a network
manager, perform the following steps:
1. Connect the terminal to the Smart 16e controller EIA-232 port. The terminal settings should match the
Smart 16e controller baud rate setting (i.e., 9600 bps, 8 data bits, no parity, and 1 stop bit).
2. Apply power to the Smart 16e controller card. Press Enter until the Login screen appears on the
terminal screen.
3. Go to the
ETHERNET CONFIGURATION menu.
4. Configure the following Smart 16e network interface settings: IP address, Subnet Mask, Gateway IP
address (if required), Trap Host IP address, GET community name, SET community name, and SNMP
Trap community name.
4. USING TELNET
The Smart 16e Shelf supports Telnet access, allowing remote access to the Smart 16e Shelf menu interface
by the network manager.
To access the Smart 16e Shelf menu interface, establish a Telnet session using the Smart 16e Shelf IP
address to open a device session. The Smart 16e Shelfs Main menu will display. Configure or monitor the
Smart 16e Shelf devices as if they were locally connected to the shelf with a VT100 terminal. Close the
Telnet application according to the network managers instructions.
5. INTERPRETING ALARMS AND STATUS MESSAGES
The four character display on the controller card front panel (Figure 25 on page 49) provides status
information about the Smart16e Shelf and the data communication cards that are installed in the shelf. If
no alarm conditions exists,
SM16 appears on the display. If an alarm condition exists, the display will
alternate between
ALM and SM16. Pressing the MODE button on the front of the controller card will
display the source of the alarm. Table 4 on page 49 lists the alarm messages.
The
STATUS LED provides a status of the Smart 16e controller card. Table 5 on page 50 lists the LED
states and their meanings.
Vista de pagina 47