Section 61245211L1-5, Issue 161245211L1-5A 1
PRACTICES
SINGLE-WIDE FT1 REPEATER
INSTALLATION/MAINTENANCE
Contents
1. General ................................................................................ 1
2. Installation ........................................................................... 3
3. Installation of FT1 Repeaters in ADTRAN
Apparatus Cases .................................................................. 3
4. Maintenance ........................................................................ 4
5. CSA Deployment Guidelines .............................................. 5
6. Specifications ...................................................................... 6
7. Warranty and Customer Service ......................................... 6
Appendix A. FT1 Loopbacks .............................................. A-1
Figures
Figure 1. ADTRAN Single-Wide FT1 Repeater ................. 1
Figure 2. ADTRAN Single-Wide FT1 Repeater
Connector Pinout .................................................. 3
Figure 3. FT1 Repeater Network Loopback ........................ 4
Figure 4. CSA Deployment Guidelines ............................... 5
Figure A-1. FT1 Loopbacks ................................................ A-1
Figure A-2. FT1 DP Network Loopback ............................ A-1
Figure A-3. FT1 DP CPE Loopback ................................... A-1
Figure A-4. FT1 Repeater Network Loopback .................. A-2
Figure A-5. FNID Network Loopback ............................... A-2
Figure A-6. FNID CPE Loopback ...................................... A-2
Tables
Table A. LED Indications .................................................... 3
Table B. FT1 Repeater Apparatus Cases............................. 3
Table C. Loop Insertion Loss Data ..................................... 4
Table D. HDSL FT1 Repeater Unit Specifications ............. 6
Table A-1. FT1 Loopback Select Codes ............................. A-3
Figure 1. ADTRAN Single-Wide FT1 Repeater
Section 61245211L1-5
Issue 1, December 1998
CLEI Code # T1R6GMJDAA
1. GENERAL
This practice provides installation and maintenance
procedures for the ADTRAN Single-Wide
Fractional T1 (FT1) Repeater, (ADTRAN P/N
1245211L1), illustrated in Figure 1.
The ADTRAN Single-Wide FT1 Repeater is a
device used to extend the effective range of an
ADTRAN FT1 circuit. It is capable of doubling the
deployment range of standard HDSL, providing a
carrier service area (CSA) compliant loop on both
sides of the Single-Wide FT1 Repeater.
Features of the Single-Wide FT1 Repeater include:
2B1Q line coding
Range up to 12 kft of 24-gauge wire each direction
from FT1 Repeater
Lightning protection
Remote loopback control
Coexists with DDS and ISDN repeaters in same
apparatus case
Remote performance monitoring capability
This unit is used in conjunction with any span
powering FT1 DP for the central office and span
powered FNID remote end as follows:
Part Number Unit Name
1245206L1 ........... Siemens FT1 DP
1245207L1 ........... Northern Telecom FT1 DP
1245208L1 ........... ALCATEL FT1 DP
1245205L1 ........... WECO D4 FT1 DP
1245201L1 ........... FNID (T400)
1242046L2 ........... Siemens FT1 DP
1242047L2 ........... Northern Telecom FT1 DP
1242048L2 ........... Alcatel FT1 DP
1242040L2 ........... AT&T FT1 DP
1242041L2 ........... FNID (T400)
1242042L2 ........... FNID (standalone)
The ADTRAN Single-Wide FT1 Repeater provides
a means of extending the digital subscriber loop
serving range using a centrally-located unit. There
are no manual option settings on the Single-Wide
FT1 Repeater.
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
FT1 REPEATER
1245211L1
1
2
3
4
5
6
7
8
9
10
11
12
GND
NC
T
R
T
R
NC
NC
NC
GND
NC
NC
CUSTOMER
LOOP 1
NETWORK
LOOP 1
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Vista de pagina 0
1 2 3 4 5 6 7 8 9 10

Indice de contenidos

Pagina 1 - INSTALLATION/MAINTENANCE

Section 61245211L1-5, Issue 161245211L1-5A 1PRACTICESSINGLE-WIDE FT1 REPEATERINSTALLATION/MAINTENANCEContents1. General ...

Pagina 2 - Table A. LED Indications

A-4 Section 61245211L1-5, Issue 1 61245211L1-5A4. LOOP-UP STATEIn the loop-up state, the active FT1 loopback willprovide a continuous loop for the FT

Pagina 3 - CUSTOMER

2 Section 61245211L1-5, Issue 1 61245211L1-5AThe ADTRAN Single-Wide FT1 Repeater providesthree faceplate LEDs which indicate signal quality,error cond

Pagina 4

Section 61245211L1-5, Issue 161245211L1-5A 32. INSTALLATIONCAUTIONThis equipment contains static-sensitivecomponents. Be sure to follow properelectr

Pagina 5

4 Section 61245211L1-5, Issue 1 61245211L1-5A4. MAINTENANCEThe ADTRAN Single-Wide FT1 Repeater requiresno routine maintenance. In case of equipmentm

Pagina 6

Section 61245211L1-5, Issue 161245211L1-5A 5Table C. Loop Insertion Loss DataFrequency Maximum Loss(Hz) (dB)3000 ... 12.010,00

Pagina 7 - FT1 LOOPBACKS

6 Section 61245211L1-5, Issue 1 61245211L1-5ALoop InterfaceModulation Type ... 2B1QMode ...

Pagina 8

A-1Section 61245211L1-5, Issue 161245211L1-5AAPPENDIX AFT1 LOOPBACKS1. GENERALThis Appendix is an overall reference to theloopback capabilities of th

Pagina 9

A-2 Section 61245211L1-5, Issue 1 61245211L1-5AThere is one loopback available to the FT1Repeater. The FT1 Repeater Network loopback is adigital loop

Pagina 10

A-3Section 61245211L1-5, Issue 161245211L1-5A3. LOOPBACK ACTIVATION ANDDEACTIVATIONThis section describes loopback activation anddeactivation methods

Comentarios a estos manuales

Sin comentarios